The completion string design was done on Oredo 11 of an onshore location of the Niger Delta. The well was spudded on April 8, 2008 and drilled as a deviated well to a total depth of 16002ft MD. Three reservoirs A-8.1, A-8.2 and B-1.0 were encountered at a depth of 13930” – 14032", 14190" – 14196" and 15759" – 15768" respectively with A-8.1 being two phase reservoir while A-8.2 and B-1.0 being single phase reservoir.
The inflow performance relationship (IPR) for reservoirs A-8.1 was calculated using Vogel correlation equation, and show that its Qmax is 1912.8 BOPD at Pwf (0 psi) while Productivity Index (PI) equation was used for reservoir A-8.2 and B-1.0, and show that Qmax is 2193.3 BOPD at Pwf (0 psi) and Qmax 1749.2 BOPD at Pwf (0 psi) respectively. The Tubing Performance Relationship (TPR) for reservoir A-8.1, A-8.2 and B-1.0 was also calculated using Gilbert Gradient Pressure Curve, the intercept of the TPR and IPR shows the optimum tubing performance for reservoir A-8.1 is 31/2" at Pwf (1100 psi) and Qmax 1680 BOPD, reservoir A-8.2 is 31/2" at Pwf (800 psi) and Qmax 800 BOPD, and reservoir B-1.0 is 23/8" at Pwf (850 psi) and Qmax 1450 BOPD. The choke performance relationship (CPR) was also calculated using F. H. Poetmann and R. L. Beck correlation curve for reservoir A-8.1 its optimum choke size is 32/64" at 1333.36 BOPD flowrate and 1800.09 psi Pwh, while Gilbert Gradient Curve and Gilbert equation for flow through choke was used for both reservoir A-8.2 and B-1.0, and show that the optimum choke size for both A-8.2 and B-1.0 is 32/64" at 1434.84 BOPD flowrate and 1000 psi Pwh for reservoir A-8.2, and 1234.69 BOPD flowrate and 958.41 psi Pwh for reservoir B-1.0.
For optimum production of Oredo 11, the completion string design indicated that, 31/2" tubing size and 32/64" choke size should be used for the short string for maximum production of 1650.07 MMSTB/D while 23/8" tubing size and 32/64" choke size for the long string for maximum production of 1666.82 MMSTB/D.

No comments:

Post a Comment